Hitemp140 TSK

  • The HiTemp140-TSK is a kit that includes a HiTemp140 data logger with either a 5.25 inch probe or a 7 inch probe style, housed in a thermal shield. The combined features of the +0.1 % accuracy of the HiTemp140 and the properties of the durable thermal shield allowthe device to be used for a wide range of validation applications. This rugged system can be placed in and withstand temperature from -200 ºC to +250 ºC, making it ideal for use in autoclave validation, monitoring food processing and dishwasher testing.Using the MadgeTech 4 software, the data logger is fast and easy to setup. Remove the thermal shield and place the HiTemp140 into the IFC400 or IFC406 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Select Start to program the settings and start the data logger. Place the thermal shield around the HiTemp140 and screw it back together. The device is ready to be deployed.The HiTemp140-TSK can be completely submerged and is built for applications that require extreme temperature monitoring.The HiTemp140-TSK flush style is designed to have the probe entirely exposed while the data logger is protected by the thermal sheild. This allows full use of the length of the probe for applications that require internal temperature monitoring. The Vented style offers more probe protection and is designed for shorter probe lengths in applications where the data logger might be subject to movement in a fully submerged application
Compare

Description

Temperature Sensor: 100 ? Platinum RTD
Probe Measurement Range: -200 °C to +260 °C (-328 °F to +500 °F)
Temperature Resolution: 0.01 °C (0.02 °F)
±0.1 °C/±0.18 °F
(20 °C to +140 °C/68 °F to +284 °F)
Calibrated Accuracy: ±0.3 °C/±0.54 °F
(-20 °C to +19.99 °C/-4 °F to +67.98 °F)
±0.4 °C/±0.72 °F
(-40 °C to -20.01 °C/-40 °F to -4.02 °F)
Start Modes: • Software programmable immediate start
• Delay start up to 18 months in advance
Stop Modes: Manual or Timed (specific date and time)
Real Time Recording: May be used with PC to monitor and record data in
real time
An optional password may be programmed into the
Password Protection: device to restrict access to configuration options. Data
may be read out without the password.
Memory: 32,700 readings
Wrap Around: Yes
Reading Rate: 1 reading every second up to 1 reading
every 24 hours
Battery Type: 3.6V high-temperature lithium battery included;
user replaceable
Battery Life: 1 year typical (1 minute reading rate at 25 °C/77 °F)
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Data Format: Date and time stamped °C, °F, K, °R
Time Accuracy: ±1 minute/month at 20 °C to 30 °C (68 °F to 86 °F)
(Stand alone mode)
Computer Interface: IFC400 or IFC406 USB docking station required; 125,000 baud
Software: XP SP3/Vista/Windows 7/Windows 8 (MadgeTech 4 Only)
Operating Environment: -40 °C to +140 °C (-40 °F to +284 °F), 0 %RH to 100 %RH
Dimensions (Body): 1.9 in x 0.97 in dia. (48 mm x 24.6 mm dia.)
Model Number: Dimensions (Probe)
HITEMP40-5.25 5.25 in x 0.188 in dia. (133 mm x 4.8 mm dia.)
HITEMP140-5.25-TD 5.25 in x 0.125 in dia. (0.188 in transitional dia.)
133 mm x 3.2 mm dia. (4.8 mm transitional dia.)
HITEMP140-7 7.0 in x 0.188 in dia. (178 mm x 4.8 mm dia.)
Weight: 4.2 oz (120 g)
Material: 316 Stainless Steel
Approvals: CE